Characteristic:
•
Permissible test load for §29 StVZO 16.0t
•
Maximum driveover load 18.0to
. 12.5kW motors
•
Brake rollers with plastic corundum coating
•
Rear test roller 50mm elevated
•
Operation via start/stop button
•
Emergency switch lockable
•
Up to 17 test programmes can be selected
•
Startup antilock device
•
Flexible line lengths enable individual
planning
•
Outdoor installation possible
Tehnical
data:
Basic
Data:
• Dimensions:
W x L x D (mm) 200 x 1250 x 410
• Weight
approx.: 750 kg
• Friction
value dry: 0.8
• Friction
value wet: 0.7
• Roller
length: 1000 mm
• Roller
diameter: 280 mm
• Largest
test width: 2900 mm
• Smallest
test width: 900 mm
• Elevation
of rear rollers to front rollers:
50 mm
• Smallest
testable wheel diameter:
. ~
450 mm (10’’)
• Largest
testable wheel diameter:
. ~
1200 mm (20’’)
• Permissible
test axle load: 16000 kg
• Permissible
max. driveover load: 18000 kg
• Maximum
braking force per wheel: 40
kN
• Noise
emission: LwA <70 dB (A
Roller
Surface:
• Expanded
metal DIN 791 (rib mesh)
. mesh
length: 62 mm
• Mesh
width: 21 mm
• Bar
thickness: 2 mm
• Bar
width: 2.5 mm
• Rib
mesh thickness: 2 mm
• Plastic
corundum coating of interstices
. with
plastic
• Plastic
coating approx:. 1 mm over rib mesh
• Grain
size: 2.0 to 3.2 mm
• Roller
colour black
Performance
Data:
• Voltage
supply: 3 x 400VAC / 60 Hz
• Nominal
output of the Dahlander motors:
. 9/12.5
kW
• Feed
line supplied: 5 x 10 mm_ (400V)
• Test
speeds: 2.6 km/h and 5.2 km/h
Optional
230V:
• Voltage
supply: 3 x 230VAC / 60 Hz
• Nominal
output of the Dahlander motors:
. 2 x 9/12.5
kW
• Feed
line supplied: 4 x 16 mm_ (230V)
• Test
speeds: 3.1km/h and 6.2km/h
Environmental
Conditions:
• Protection
class:
. (according
to DIN 40 050) IP 54
• Permissible
humidity (relative without
. condensation): up to 85%
• Operating
temperature: 10 to +60 °C
• Storage 10 to +60 °C